What was found
STRINGER AT 24R IS CORRODED BETWEEN BS 333.- 349. BLENDED CORROSION ON STRINGER IAW SRM 51-21-06-001-001-A01. NO DAMAGE IS ALLOWED TO STRINGER 24R IAW SRM 53-21-03-101-006-A01. PERFORMED UT THICKNESS ON REWORKED AREAS ON STRINGER IAW NDTM PT 1 51-20-004-270-A01. FOUND LOWEST REMAINING THICKNESS TO BE .048" OR GREATER. COMPLIED WITH STEPS 1-2 CUT & REMOVED STRINGER 24R IAW SRM 53-00-03-201-001-A01 PG.205. DRILLED AND LOCATED COMPLETED IAW SRM 53-00-03-201-001-A01, SRM 51-40-11-001-001-A01. COMPLIED WITH STEPS 4-13 SHIM, REPAIR ANGLE MADE IAW SRM 53-00-03-201-001-A01. COMPLIED WITH REMAINING STEPS OF 14 THRU COMPLETION OF INSTALLING THE STRINGER IAW SRM 53-00-03-201-001-A01.