What was found
FOUND ELONGATED FASTENER HOLES ON STGR 21L BETWEEN FS 333.00-FS349.00. REMOVED AND REPLACED SKIN RIVETS FROM STGR 21L FS333- FS485 IAW CRJ700 SRM 51-42-06-001-001-A01. REMOVED AND REINSTALLED FLOOR LEVEL INTERCOSTAL AT FS364-FS379 LBL 37, STRAP ON STGR21L AT FS333, GUSSETS ON STGR21L AT FS 379/ 364, SPLICE ON STGR21L AT FS379, IAW CRJ700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. REMOVED AND REPLACED STGR 21L IAW SRM 51-42-06-001-001-A01. AND SRM 51-42-21-001-001-A01. FABRICATED, LOCATED AND DRILLED NEW SERVICEABLE STGR 21 IAW SRM 51-24-36-001-001-A01 AND SRM 51-40-11-001-001-A01.