What was found
RBL 9 FLOOR SUPPORT IS CORRODED BETWEEN F.S. 501 - 549. R & R ENTIRE FLOOR SUPPORT RBL 9 FS 477 - 571 IAW MHI RJ REO 670-53-31-1054 REV --. FABRICATED RBL9 FLOOR SUPPORT FROM FS 477 - 571 USING EXTRUSION, LOCATED, DRILLED UPPER & LOWER FLANGE IAW SRM 53-00-41-201-001-A01. FABRICATED, LOCATED & DRILLED ITEM 11 CLEATS FOR NEW FLOOR SUPPORT FROM RBL 9 FS 477 - 549 IAW SRM RM 53-00-41-201-001-A01 5B(5-6) & 5B(19). MANUFACTURED REPAIR ITEM -5 LOWER SPLICE, -6 SHIM, -7 SHIM IAW REO 670-53-31-1054, REV --P1, APPLIED PAINT AT REPAIR PARTS IAW CRJ700 SRM 51-25-21-001-001-A01"