What was found
INITIAL INSPECTION: CORROSION ON CLOSING FITTINGS (2EAS) BTW FS 314.00 AND FS 342.00 AND STGR 18L. CORROSION ON CLOSING FITTINGS (2EAS) BTW FS 314.00 AND FS 342.00 AND STGR 18L WERE REMOVED PER CRJ900 SRM 51-21-06-001-001-A01, CLOSING FITTINGS FWD WAS EVALUATED OUT LIMITS PER CRJ-900 SRM 53-21-23-101-001-A02 THEREFORE WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND CLOSING FITTINGS AFT WAS EVALUATED WITHIN LIMITS PER CRJ-900 SRM 53-21-23-101-001-A02