What was found
CORROSION ON SETTLEMENT AREA OF BODY FAIRING SUPPORTS BTW FS881.00 AND FS 847.00. CORROSION ON SEATTLEMENT AREA OF BODY FAIRING SUPPORTS BTW FS881.00 TO FS 847.00 +16.00 WAS REMOVED PER CRJ/900 SRM 51-21-06-001-001-A01 AND WERE EVALUATED WITHIN LIMITS PER CRJ-900 SRM 53-00-00-101-001-A01 AND SEATTLEMENT AREA OF BODY FAIRING SUPPORT (DOOR LANDING) BTW FS 847.00 WAS EVALUATED OUT LIMITS PER CRJ/900 SRM 53-82-55-101-002-A02 THEREFORE WAS REPLACED PER CRJ900 SRM 51-42-10-001-001-A01