What was found
CORROSION ON STUB FRAME AT FS 533.00 AND FS 549.00 APROX STGR 18 LH AT SURROUND STRUCTURE OF FWD BAGGAGE BAY DOOR STUB FRAME AT FS 533.00 AND FS 549.00 APROX STGR 18 LH AT SURROUND STRUCTURE OF FWD BAGGAGE BAY DOOR WERE EVALUATED OUT LIMITS PER CRJ 900 SRM 51-10-06-001-001-A01 THEREFORE WERE REPLACED PER CRJ 900 SRM 51-42-20-001-001-A01, SRM 51-42-21-001-001-A01 AND SRM 51-42-06-001-001-A01