What was found
CORROSION AT LOWER SILL, SEAL STRIKER & MOUNTING ANGLES OF WEB FLOOR PROTECTOR BTW FS 320.00 TO FS 349.00 OF SERVICE DOOR SURROUND STRUCTURE. CORROSION AT LOWER SILL, SEAL STRIKER & MOUNTING ANGLES OF WEB FLOOR PROTECTOR BTW FS 320.00 TO FS 349.00 OF SERVICE DOOR SURROUND STRUCTURE WAS REMOVED PER CRJ-900 SRM 51-21-06-001-001-A01, LOWER SILL AND MOUNTING ANGLES WERE EVALUATED WITHIN LIMITS PER CRJ-900 SRM 53-21-23-101-002-A02, SEAL STRIKER WAS EVALUATED OUT LIMITS PER CRJ-900 SRM 53-21-23-101-002-A02, SEAL STRIKER WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01