What was found
CORROSION ON ANGLES BS 847+32 BTW STG 17R TO 17L. CORROSION ON ANGLES BTW BS 847+32 & 847+64 AND RBL 18 LBL 18. CORROSION ON ANGLE BS 794 BOTTOM SIDE AND RBL 46 LBL 46. CORROSION ON ANGLES BS 847+32 BTW S17R TO 17L. CORROSION ON ANGLES BTW BS 847+32 & 847+64, RBL 18 & LBL 18. CORROSION ON ANGLE BOTTOM SIDE, & RBL 46, LBL 46, REMOVED IAW SRM 51-42-10-001-001-A01, BS 847+32 BTW S17R TO 17L, 847+32 (DOOR LANDING) EVALUATED OUT LIMITS IAW SRM 53-82-55-101-002-A02. REPLACED IAW SRM 51-42-10-001-001-A01, ANGLES BTW BS 847+32, & 847+64 EVALUATED WITHIN OF LIMITS IAW SRM 53-82-55-101-002-A02, & SETTLEMENT OF FAIRING PANEL BS 794 (FRAME ASSY) EVALUATED OUT LIMITS IAW SRM 53-00-01-101-001-A01, REPLACED IAW SRM 51-42-21-001-001-A01