What was found
CORROSION ON ANGLE SETTLEMENT AREA OF FAIRING PANEL STA=693 RBL=45 TO LBL=45 /// CORROSION ON ANGLE SETTLEMENT OF FAIRING PANEL FS= 661+90 LBL=40 TO RBL=40 /// CORROSION ON ANGLE SETTLEMENT OF FAIRING FS=661+62 RBL=45 TO LBL=45 ALSO CORROSION ON ANGLE SETTLEMENT AREA OF FAIRING PANEL LBL=0 BTW STA=661+90 TO STA= 661+62 SUMMARY: CORROSION ON ANGLE SETTLEMENT AREA OF FAIRING PANEL BTW STA=693 RBL=45 TO LBL=45 , FS= 661+90 LBL=40 TO RBL=40 , AND FS=661+62 RBL=45 TO LBL=45 WAS REMOVED AND EVALUATED WITHIN OF LIMITS PER CRJ-900 SRM 51-21-06-001-001-A01 AND CRJ-900 SRM 53-82-55-101-001-A01 AND ON ANGLE SETTLEMENT BTW LBL=0 BTW STA=661+90 TO STA= 661+62 IS OUT OF LIMITS THEREFORE ANGLE SETTLEMENT WAS REPLACED PER CRJ-900 SRM 51-42-06-001-001-A01