What was found
CORROSION ON STRIPS OF FAIRINGS 192BB, 193AB & 196DR ALSO LOOSE FASTENERS ON STRIP OF FAIRINGS ACCESS 196DR. STRIPS (2EAS) OF FAIRING 193AB WERE REPLACED PER CRJ-900 SRM 51-42-10-001-001-A01, STRAP OF ACCESS PANEL 196DR WERE REPLACED AND FASTENERS WERE INSTALLED PER CRJ-900 SRM 51-42-10-001-001-A01, AND STRAP OF FAIRING 192BB WITH P/N: CC670-39170-1 WAS FABRICATED PER BOMBARDIER DWG: CC670-39170 REV. A AND EA NO: CRJ953-22731 REV. IR