What was found
CORROSION ON STGR=20R, FS=295 TO FS=319, FS=349 TO FS=370 AND FS=445 AT FWD E/E CORROSION ON STGR=20R, FS=295 TO FS=319, FS=349 TO FS=370 AND FS=445 AT FWD E/E WERE EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-10-06-001-001-A01, THEREFORE STRINGER 20R BTW FS280 TO FS477.4 WERE REPLACED PER CRJ900 SRM 51-42-06-001-001-A01,CRJ900 SRM 51-42-21-001-001-A01 AND CRJ900 SRM 51-42-10-001-001-A01.