Service difficulty report · Pump · Saab SF340A

Difficulty date
October 2, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N112PX
Make and model
Saab SF340A
Aircraft serial
340A025
Part
Pump
Part number
4018502
Condition
Failed
Location
Hyd System
Stage of operation
CL
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LOSS OF ELECTRIC HYDRAULIC PUMP MANUAL AND OVERRIDE. EMERGENCY LANDING. SWAPPED INTO 401. REMVOED AND REPLACED ELECTRIC HYDRAULIC PUMP IAW AMM 29-10-00. NO LEAKS NOTED. OPERATIONAL CHECKS GOOD. (M)