What was found
EXCESSIVE ELEVATOR CONTROL INPUT REQUIRED DURING LANDING FLARE. MAINTENANCE VISUALLY INSPECTED CABLES AND PULLEYS, NO DAMAGE NOTED. FERRIED AIRCRAFT TO MAINTENANCE BASE. REMOVED AND REPLACED ELEVATOR FEEL UNIT AND ELEVATOR PACK FILTERS. PERFORMED ALL OPERATIONAL CHECKS AND FUNCTIONAL CHECKS IAW BOEING MM 27-30-0, 27-30-81, AND 27-20-11. ALL CHECKS SATISFACTORY. AIRCRAFT RETURNED TO SERVICE. (X)