What was found
PSM, NR 1 ENG NOSE COWL IS DENTED BEYOND ALLOWABLE LIMITS AT NAC STA 98 AT THE 9 O''CLOCK POS. REP THE AFFECTED AREA BY THE INSTALL OF A FLUSH TYPE REP. ALL WORK WAS ACCOM IAW BY THE FOLLOWING: 1) REMOVED THE DAMAGED AREA IAW THE SRM 54-30-3 FIG 2. FABRICATED THE FILLER, DOUBLER AND SHIMS IAW THE SRM 54-30-3 FIG 2 & 51-30-6. ALODINED AND PRIMED THE REP PARTS AND THE REP AREA IAW THE SRM 51-10-2 & MM 51-20-31. PREPPED THE REP PARTS AND THE REP AREA FOR BONDING IAW THE SRM 51-40-5. INSTALLED THE REP PARTS TO THE REP AREA IAW SRM 51-30-2, 51-40-5 & 54-30-3 FIG 2. RESTORED THE AERODYNAMIC SMOOTHNESS TO THE REP AREA IAW SRM 51.