What was found
MQY - FOUND FLOORBEAM CORRODED AT STATION 1110 FROM LBL 45 INCHES TO RBL 20 INCHES HAS BEEN BLENDED TO LIMITS IAW B727 SRM 53-10-1, FIG 4. CORROSION STILL EXISTS IN AREA. REMOVED AND REPLACED UPPER T-CHORD AT STATION 1110 LBL 69 TO RBL 34.5 IAW B727 SRM 53-10-8, 51-10-2 AND EO NR 01-298 WITH APPROVED 8110-3. APPRECIABLE WEIGHT ADDED BY THIS REPAIR IS .480 LB AT STATION 1110. (M)