What was found
ENG 1 CTL VALVE FAULT // IN REFERENCE TO TSM 75-33-00-810-811-A THE RESISTANCE AND INSULATION CHECK ON THE EEC A ELECTRICAL HARNESS CONECTOR P8A WAS FOUND. SOCKETS J AND -D (LOWERCASE) (BETWEEN 21 AND 39 OHMS) = 34.9 OHMS SOCKETS -V (LOWERCASE) AND -B (LOWERCASE) (BETWEEN 10 AND 18 OHMS) =16.5 OHMS SOCKETS -C (LOWERCASE AND -B (LOWERCASE) (BETWEEN 10 AND 18 OHMS) = 16.6 OHMS SOCKETS -B (LOWERCASE) AND THE GROUND (MORE THAN 10 MOHMS) = OK SOCKETS -C (LOWERCASE) AND THE GROUND (MORE THAN 10 MOHMS) = OK SOCKETS -D (LOWERCASE) AND THE GROUND (MORE THAN 10 MOHMS) = OK SOCKETS J AND THE GROUND (MORE THAN 10 MOHMS) = OK SOCKETS -V (LOWERCASE) AND THE GROUND (MORE THAN 10 MOHMS) = OK ON TBV RECEPTACLE CONNECTOR J86 THE RESISTANCE AND INSULATION WAS FOUND. PINS A AND 12 (BETWEEN 21 AND 39 OHMS) = 33.7 OHMS PINS 10 AND 11 (BETWEEN 10 AND 18 OHMS) =15.3 OHMS PINS 3 AND 11 (BETWEEN 10 AND 18 OHMS) = 15.4 OHMS PIN 3 AND THE GROUND (MORE THAN 10 MOHMS) = OK PIN 4 AND THE GROUND (MORE THAN 10 MOHMS) = OK PIN 10 AND THE GROUND (MORE THAN 10 MOHMS) = OK PIN 11 AND THE GROUND (MORE THAN 10 MOHMS) = OK PIN 12 AND THE GROUND (MORE THAN 10 MOHMS) = OK AND ALSO THE RESISTANCE BETWEEN TBV-P86 TO P8A CONNECTOR ON ECC CH A J TO 4 = 0.7 OHMS -D (LOWERCASE) TO 12 = 0.7 OHMS -V (LOWERCASE) TO 10 = 0.7 OHMS -B (LOWERCASE) TO 11 = 0.8 OHMS -C (LOWERCASE) TO 3 = 0.7 OHMS BETWEEN TBV J86 TO J812 CROSSLINK FROM HJ8A TO HJ8B EEC CH B 17 TO 6 = 0.7 OHMS 18 TO 7 = 0.7 OHMS 21 TO 2 = 0.7 OHMS 22 TO 8 = 0.8 OHMS 23 TO 9 = 0.8 OHMS // IAW TSM 75-33-00-810-807-A WAS REPLACED SPLIT CONTROL UNIT AND SERVO VALVE ASSY (SCU/SVA) FIN 4186KS IAW AMM 73-21-10-000-802-A / 73-21-10-400-802-A REV 59 . TORQUE APPLIED: SCU SUPPORT BRACKETS BOLTS: 120 LBF. IN , VBV-VSV FUEL MANIFOLD BOLTS : 120 LBF. IN , MTC ACC FUEL MANIFOLD BOLTS. 120 LBF. IN , SUPPLY HOSE B-NUT 32 : 530 LBF. IN , MAIN SUPPLY HOSE B NUT 16: 1000 LBF. IN , SECONDARY SUPPLY HOSE B-NUT : 730 LBF.