What was found
DURING FLIGHT CREW NOTICED FUEL DISCREPANCY OF 500 KG AND 350 KG BETWEEN TANK>>>PERFORMED SAMPLE FUEL FOR MICROBIOLOGICAL CONTAMINATION ANALYSIS RESULTS ARE NEGLIGIBLE NO CURATIVE TREATMENT IS NECESSARY. WAS REPLACED WING-TANK FUEL-QUANTITY PROBE 34QT1. PERFORMED ELECTRICAL RESISTANCE MEASUREMENT FOUND WITHIN OF LIMIT WITH LESS THAN 08 MILLIOHMS. PERFORMED STATUS REPORT (BITE) OF THE FQI SYSTEM NO FAULTS DETECTED ALL OK AND PERFORMED FUNCTIONAL (BITE) TEST OF THE FUEL LEVEL SENSING SYSTEM (FLSS) TEST OK NO FAULT DETECTED