DURING A MAINTENANCE VISIT FOUND ELONGATED HOLE, UPPER CARGO COMPT AT FS 1215 XCW 44.5 L/H SEAT TRACK. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3.