What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, UPPER CARGO COMP AT STA 902 XCW 59 RT PRESS WEB ATTACH DOUBLER HAS SMALL AREA OF EXFOLIATION. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.