What was found
DURING MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT STA 70.0 AFT OF L1 DOOR. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 51-3-3, 53-2-3 AND 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).