What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ATTACHMENT ANGLE AT STA 1060 AND LONGERON 36, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ATTACHMENT ANGLE IAW DC-8 SRM 51-1-20.