What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ATTACHMENT ANGLE AT STA 1540 BL-R 40 AND WL-15, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ATTACHMENT ANGLE IAW DC-8 SRM 51-1-21.