What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO 2 EACH BRACKETS AT STA -131 AND LONGERON 23 LEFT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.