What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FWD CARGO FRAME AT STA 120 AND STR 30R AND 27R, DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED DAMAGED FRAME, TREATED AREA IAW DC8 SRM 51-1-8, INSTALLED IAW DC8 SRM 53-2-0 FIG 1. CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.