What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO RT CARGO TIE DOWN AT STA 365 AND LONGERON 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED TRACK IAW DC8 SRM 51-1-24, 51-1-8, 51-3-2, 53-2-3 FIG 12. TREATED AREA IAW DC8 SRM 51-1-8. CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.