What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO AFT CARGO SKIN CLIP AT STA 1260 AND LONGERON 36L - 35L, DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLED IAW DC8 SRM 51-1-4 AND 51-1-8 FIG 7 & 8. CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.