What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO AFT CARGO SKIN CLIP AT STA 1240 AND LONGERON 34L TO 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLED IAW DC8 SRM 53-4-0 FIG 7 & 8. CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.