What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK BETWEEN STA 70 TO STA 1705 AND BL 0 , DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION IAW DAC DWG 5750864.