As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA 1150 BETWEEN LONGERONS 34 RIGHT TO 35 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-2-0 FIGURE 2D. CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.