What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SHEAR TIE AT STA 35, AND IN BETWEEN LONGERON 35 LEFT TO 34 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SHEAR TIE IAW DC-8 SRM 51-1-21 AND DAC DWG NR 5613836. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).