What was found
DURING A MAINTENANCE VISIT, FOUND MODERATE CORROSION DAMAGE TO LEFT AFT T1 DOOR FITTING AT LONGERON 1 TO 6 LEFT AND AFT END OF DOOR, DAMAGE WAS WITHIN LIMITS IAW DC-8 SRM. REMOVED DAMAGED FASTENERS, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED FASTENERS IAW DC-8 SRM 20-15-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).