What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO MAIN DECK SEAT TRACK AT STA 55 TO 310 AND LBL 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED SEAT TRACK SECTION IAW DC-8 SRM 53-2-3 FIG 8A. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).