What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN DECK SEAT BETWEEN STA 1010 TO 1090 LONGERON LBL 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM 51-1-8. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED SEAT TRACK SECTION AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 8A. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).