What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN DECK SECTION OF SEAT TRACK BETWEEN STA 130 TO 270 RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED MAIN DECK SECTION OF SEAT TRACK AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 8A DAC DWG NR 5750864. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).