What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN DECK SEAT TRACK BETWEEN STA 270 TO 450 RBL 48, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SEAT TRACK SECTION IAW DC-8 SRM 53-2-3 FIG 8A DAC DWG 35750864. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).