What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SEAT TRACK GANG CHANNEL AND SPLICE AT STA 430 AND LONGERON BL-L 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 8A AND DAC DWG NR 54932154T. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).