What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING AT STA 320 AND BETWEEN LONGERONS 34 RIGHT AND 33 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-2-0 FIG 2D AND SRM 51-1-20D. (CORROSION PROGRAM RECORDED IN EWA CORROSION PROGRAM).