What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO RT CUSP AT STA 1010 TO 990. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED RT CUSP SECTION IAW DC-8 SRM 53-2-5 FIG 15. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).