What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE SHEAR TIE AT STA 280 AND BETWEEN LONGERONS 33 RIGHT TO 34 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW SHEAR TIE PER DWG NR 3755824. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).