What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE UNDER NUT PLATES AT STA 1000 AND LONGERON L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED, REPAIRED AND INSTALLED IAW DC-8 SRM 53-2-0 FIG 2 AND DAC DWG 2750825. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).