What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN DECK SEAT TRACK AT STA 680 TO 820 AND RBL 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 8A. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).