What was found
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE RIGHT WING L/E RIB AT THE AFT LOWER FASTENERS AT STA XFS 660.0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED, REPAIRED AND INSTALLED IAW DC-8 SRM 57-2-0 FIG 2.