What was found
DURING A MAINTENANCE VISIT FOUND A DEEP DENT AND CRACK AT THE RT HORIZONTAL STAB UPPER PLATING JUST FWD OF ACCESS HOLE AT STA XE 36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0 AND DAC DWG NR 5653617.