What was found
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE LEFT WING L/E RIBS AFT FASTENERS AT STA XFS 741.250, 747.500. 753.750 AND 760.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED, REPAIRED AND INSTALLED IAW DC-8 SRM 57-2-0 FIG 2.