What was found
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE RT WING L/E RIB AT STA 822.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 53-2-0 FIG 1B, 51-1-21D, 51-1-8 AND 06-00-00.