What was found
DURING A MAINTENANCE VISIT FOUND A CRACK TO RIB STIFFNER 16 IN. INBD OF LT MLG ACTUATOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW STIFFNER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT FOUND A CRACK TO RIB STIFFNER 16 IN. INBD OF LT MLG ACTUATOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW STIFFNER.