What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT STA 1460 AND LONGERON 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED STRAP DOUBLER FROM 7075-T6 AND INSTALLED PER EO NR 99-236 WITH APPROVED 8110-3 DATED 12-6-99.