What was found
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILL HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING HOLES USING AD RIVET MATERIAL, FABRICATED REPAIR STRAP DOUBLERS FROM 7075-T6 AND INSTALLED IAW EO NR 99-236 WITH APPROVED 8110-3 DATED 12-21-99.