What was found
DURING A MAINTENANCE VISIT, FOUND TWO SCREWS NOT INSTALLED IN RT WING L/E BETWEEN STA XFS 26.250 AND 63.750 (EO), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8, INSTALLED FASTENERS IAW DC-8 SRM 51-1-20C AND EO NR 99-236 WITH APPROVED 8110-3 DATED 3-30-00.