What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AROUND SCREW HOLES LT WING I/B LEADING EDGE UPPER SURFACE AT STA XFS 13.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLER FROM 7075-T6 AND INSTALLED IAW DC-8 SRM 57-2-0, 57-2-1, 51-1-20D, 51-1-21 AND EO NR 99-236. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).